TermWhat it means hereIntroduced in
Air barrierThe layer that stops air moving through a wall, roof or floor assembly. Caulk, sealant, gaskets and weatherstripping are air barrier work. It is a different job from insulation, and DOE's order is to do it first.How the systems work
AFCIArc-fault circuit interrupter. A device, found as an outlet or a breaker, that opens a circuit on the electrical signature of an arc, which is a fire hazard.How the systems work
Anode rodA sacrificial metal rod inside a water heater tank. Its reaction with sulfate in some water produces the rotten egg smell found in hot water only. Removing it may void the heater's warranty.Heating, cooling and hot water
BackdraftingCombustion products coming back down a flue into the house instead of going up it. Caused by a blockage, a disconnection, or the house being depressurized by something else such as a powerful exhaust fan.Heating, cooling and hot water
Building envelopeSee shell.How the systems work
CADRClean air delivery rate, the rating for a portable air cleaner. EPA notes that the CADR chart assumes an 8-foot ceiling, that the rating system is for particles only, and that no widely used rating exists for removing gases.Air, moisture and insulation
CondensationWater coming out of humid air onto a surface cold enough that the air can no longer hold it. It appears at a house's coldest surfaces, which is why the fix is some combination of less moisture, more ventilation and a warmer surface.Air, moisture and insulation
Combustion airThe air a fuel-burning appliance needs to burn with. Where it comes from is part of the appliance's design, and blocking it is one way an appliance stops burning cleanly.How the systems work
Data plateThe metal or foil label a manufacturer puts on equipment, carrying the make, the model number, the serial number and the ratings. The single most useful object in a house for planning.Walk your house
Deferred maintenanceWork that is needed and has not been done. The difference between deferred and forgotten is a written record: the row, the tier, the reason and the date you will look again.The priority rule
DWVDrain, waste and vent: the drain side of a house's plumbing, including the vent piping that lets air in so draining water does not siphon the traps dry.How the systems work
DrainfieldThe part of a septic system where liquid from the tank soaks away into the ground.How the systems work
EfflorescenceA white powdery mineral deposit left on masonry where water evaporated out of it. Evidence that water has been moving through the material.Walk your house
EnergyGuide labelThe yellow label required by 16 CFR part 305, carrying estimated annual energy consumption, estimated annual operating cost, an efficiency rating and, where it applies, a water use rate, with ranges across comparable models.Choosing and keeping appliances
FlueThe path that carries the products of combustion out of a building. Distinct from a plumbing vent and from a dryer duct, both of which are also sometimes called vents.How the systems work
Footing drainDrainage installed around a foundation's footing to carry groundwater away. Kansas State cites a study finding improperly installed footing drainage in more than 90 percent of wet basement cases, and it is the part a householder cannot inspect.Keeping water out
GFCIGround fault circuit interrupter. A device, found as an outlet or a breaker, that opens a circuit when current is leaking to ground, which is the shock hazard. Why they appear near water.How the systems work
GradeThe slope of the ground surface next to a foundation. University of Minnesota Extension's minimum is 1 inch per foot for at least 6 feet; Kansas State's ideal is about 1 inch per foot for 15 feet.Keeping water out
HygrometerAn instrument that reads relative humidity. EPA prices a moisture or humidity meter at $10 to $50 at hardware stores.Air, moisture and insulation
Ice damA ridge of ice at a roof edge that stops meltwater draining, so water backs up under the roof covering. A heat-loss problem rather than a roof problem: heat escaping into the roof deck melts snow that refreezes at the colder eave.Air, moisture and insulation
IECC climate zoneA number from 1 to 8, with marine subdivisions, used to organize building energy requirements and DOE's insulation table. This manual uses the 2012 IECC edition's map, because zone boundaries changed between editions.Your own calendar
Lead-safe certified firmA firm certified under EPA's Renovation, Repair and Painting rule, which requires certification of anyone paid to disturb painted surfaces in pre-1978 homes, childcare facilities and preschools, including sole proprietorships.Alarms, vents and tests
Mechanics lienA claim against a property by somebody who supplied labor or materials and was not paid. The rules about who can file one, when, and with what notice are state law and vary a great deal.Hiring help
MERVThe rating scale for how much of what size particle a filter captures, higher capturing more. EPA recommends at least MERV 13, or as high as your system will accommodate.Air, moisture and insulation
pCi/LPicocuries per liter, the unit for radon concentration in the United States. EPA recommends fixing a home at 4 pCi/L or more, and considering a fix between 2 and 4.Alarms, vents and tests
Pressure reducing valveA valve near the main shutoff that lowers incoming water pressure. We found no agency or extension source giving a homeowner a target range, so this manual states none and the question goes to a plumber or the utility.How the systems work
R-valueA measure of insulation's resistance to heat flow, higher being more insulating. DOE says it depends on the type of insulation and the thickness, and that it is printed on the packaging or the paper backing.Air, moisture and insulation
Relative humidityHow much water vapor air holds as a percentage of what it could hold at that temperature. EPA says to keep indoor humidity below 60 percent, ideally between 30 and 50.Air, moisture and insulation
Relief valveThe temperature and pressure relief valve on a water heater, which opens if pressure or temperature goes too high. UGA lists testing it as a homeowner check; a valve that will not reseat discharges scalding water until the supply is shut off.Heating, cooling and hot water
SeepageWater coming through masonry into a basement or crawl space, as distinct from condensation on its surface or groundwater arriving at the floor. The foil test tells the three apart.Keeping water out
SedimentDirt and mineral deposits that build up inside a water heater tank. University of Missouri Extension's remedy is periodic flushing, from monthly in hard water to once a year elsewhere.Heating, cooling and hot water
Service lifeA published estimate of how long a component typically lasts. InterNACHI's chart is the one this manual reproduces, and it carries no publication date and no methodology, which is stated on every row.What wears out and when
Service contractWhat FTC says a home warranty really is: cover for replacements and repairs for a set period, which unlike a builder's warranty or a warranty included with a product costs extra.Hiring help
ShellThe building envelope: the boundary between conditioned inside air and the outdoors, made of the roof, walls, windows, doors and the floor or foundation.How the systems work
Sinking fundMoney set aside for a known future expense on a known rough schedule, which is what the reserve in this manual is. Different from an emergency fund, which covers the unknown.What wears out and when
Service sizeThe electrical capacity of a house, in amps, stamped on the main breaker. Commonly 100, 150 or 200. The first question asked by anybody quoting electric heating, an electric water heater, a range or a car charger.How the systems work
TrapThe U-bend under a fixture that holds a plug of water so sewer gas cannot come back up the drain. A trap in an unused fixture evaporates, which is why a cup of water is the fix.How the systems work
TierThis manual's ranking of upkeep by what a failure does: water going where it should not, failures that are not recoverable, equipment that fails expensively on a schedule, money that leaks every day, and what only looks bad.The priority rule
Vapor retarderA layer that slows water vapor diffusing through an assembly. Which side of the assembly it belongs on, or whether it belongs there at all, depends on the climate, and this manual leaves the question to somebody designing assemblies where you are.Air, moisture and insulation
VentUsed three ways. In plumbing, the piping that lets air into a drain system. In combustion, loosely for a flue. In laundry, the dryer's duct. Ask which is meant before agreeing to anything.How the systems work

Terms this manual deliberately does not define

A few words appear in home maintenance advice carrying a precision they do not have, and this manual avoids them rather than defining them.

  • "Up to code." Codes are adopted, amended and enforced locally, and what applied when a house was built is not what applies now. Your local building department is the only authority on it.
  • "Normal wear." Used in insurance and in leases, and defined by the policy or the lease rather than by any general meaning.
  • "Lifetime warranty." Whose lifetime, and covering what, is in the warranty document. Choosing and keeping appliances covers the law behind written warranties.

The full source list behind every figure in this manual is in the resource library, with the date each link was last fetched.