How the systems work
What you have

How a house works: water in, water out, air, heat and power

Six systems, each traced from where it enters to where it leaves, with its own control, its own failure signs, and a clear line between what you can touch and what you cannot.

Start here Essentials

At minimum, trace three paths and write down what you find. The heat pump physics, the pressure reducing valve, the vent and flue distinction and the condo boundary are all Go deeper.

  1. Follow the water from the meter to the water heater and write where the main shutoff is (water in).
  2. Find the filter in the air path and note its size off the edge of the old one (air).
  3. Find the main breaker and note the service size stamped on it, with the panel cover left in place (power).
  4. Write down which heating arrangement you have, or "don't know" and read that section (heat and cooling).

Minimum time: about 45 minutes. Done when: the systems sheet names your heating arrangement, your water heater type and your filter size.

1. Five questions to ask of any system Understand

A house is six systems sharing a box. Each one brings something in, does something with it, and sends something out, and each one has a place where you can stop it. Once you can trace all six, most of what a technician says to you stops being opaque, and most of what a maintenance list tells you to do stops being arbitrary.

The chapter is a map, and a map is read with five questions. Ask them of every system here, and of any system this manual does not cover:

  1. Where does it come in and where does it go out? Every system has two ends, and the ends are usually visible.
  2. What is its control? A valve, a breaker, a switch, a damper. If you cannot find the control, that is the first thing to find out.
  3. What can you see? The parts that are in the open, which is where almost all homeowner maintenance happens.
  4. What can you test? A meter reading, a thermometer, a hygrometer, a press of a button. A test gives you a number, and a number is what turns an impression into a record.
  5. What must you not touch? The short list is the same in every house: fuel, flue, panel, refrigerant, pressurized connections. The who-to-call table names who does each.

And one more thing per system, which is the one worth memorizing: the symptom that means call somebody today rather than putting it on a list. Those are collected at the end of each section below.

Limits

This chapter is a map, not a repair manual. Knowing how a flue works is not permission to inspect one, and tracing a gas line is not a reason to put a wrench on it. The sections below say what each system's symptoms mean and who reads them; none of them teaches a repair on gas, flues, panels, refrigerant or pressurized plumbing.

2. Water in

Water arrives under pressure and goes wherever a path opens, which is why it is both the most useful system in a house and the one that does the most damage.

The path. From a public main or a private well, through a meter (on a public system) or a pump and pressure tank (on a well), through the main shutoff, then splitting: cold branches to every fixture, and one branch to the water heater, from which hot branches run back out to the fixtures that need hot water. Each fixture usually has its own small stop valve underneath it, so one sink can be isolated without shutting the house.

The control. The main shutoff, then the fixture stops. Find both; Walk your house is the exercise.

What you can test. The meter, and this is the single most useful test in this manual. A water meter counts volume, in cubic feet or in gallons depending on the utility, and most have a small dial or a triangle that turns on any flow at all. Shut everything off in the house, read the meter, wait, read again. EPA WaterSense builds its own leak advice on the same fact, reporting that nine percent of homes have leaks wasting 50 gallons a day or more, and that a family of four using over 12,000 gallons in a winter month may have serious leaks. The leak calculator turns two readings into gallons a day.

What you do not touch. The connections themselves, under pressure. A compression nut that is weeping can be tightened a flat; a supply line that is bulging gets replaced by somebody who does it for a living, and a water heater's connections are in Heating, cooling and hot water for a reason.

Ask the authority Static water pressure is read with a gauge screwed onto a hose bib, and the reading is easy to take. What it should be, and whether your house needs a pressure reducing valve, is a question for a plumber or your water utility: we found no agency or extension publication giving a homeowner a range, so this manual gives none. If you take a reading, write it on the log and ask somebody what it means.

Call somebody today if: water is running and you cannot stop it; the main will not close; hot water smells strongly of rotten eggs and the cold does not (an anode rod symptom, covered in Heating, cooling and hot water); or the meter is spinning with every fixture closed.

3. Water out

The drain side is called DWV, for drain, waste and vent, and the vent is the part nobody expects. Every drain in a house runs downhill to a common stack and out to a sewer or a septic tank. Each fixture has a trap, the U-bend that holds a plug of water so sewer gas cannot come back up through the drain. And every trap needs air behind it, supplied by vent piping that runs up through the roof, or the draining water pulls the trap dry by siphon.

Physical principle That is why a house makes gurgling noises when one fixture drains and another burps, and why a floor drain or a guest bathroom that is never used eventually smells: the trap has evaporated. The fix for the second one is to pour a cup of water down it, which is the cheapest maintenance task in this manual and belongs on your calendar if you have a drain you never use.

Where it goes. Two answers. A public sewer, where the house's responsibility ends at a property-line connection whose exact location and ownership is a question for the utility. Or a septic system: a tank where solids settle and scum floats, and a drainfield where the liquid soaks away. EPA describes both the conventional tank-and-drainfield arrangement and alternative systems with pumps, float switches or mechanical components, and the distinction matters because the inspection interval depends on it. EPA says the average household septic system should be inspected at least every three years and is typically pumped every three to five, while a system with electrical float switches, pumps or mechanical components should be inspected more often, generally once a year.

The control. There usually is not one, which is worth knowing. A house has no shutoff on the drain side. A backup is stopped by stopping what goes into it.

Call somebody today if: more than one fixture is draining slowly at once (a main line problem rather than a sink problem); anything is backing up at the lowest fixture in the house; or there is standing water or a smell over a septic drainfield.

4. Air

If your house has ducts, air is a loop. A return grille pulls house air back to the equipment, the air passes through a filter, then over a heat exchanger or a coil, and a blower pushes it out through supply registers into the rooms. The loop is almost closed: the system mostly moves the same air around rather than bringing new air in.

That is the sentence that makes the rest of the house's air rules make sense.

  • The filter protects the equipment first. It sits where it does because the blower and the coil need clean air, not because the house does. ENERGY STAR's maintenance checklist puts it plainly: a dirty filter slows airflow, makes the system work harder, and lets dust build up in the system, which it links to expensive maintenance and early system failure.
  • Filtration and ventilation are different things. A better filter cleans the air that is already inside. It does not bring fresh air in. EPA names three basic strategies for improving indoor air quality, which are source control, improved ventilation and air cleaning, and notes that source control is also a more cost-efficient approach than increasing ventilation, because increasing ventilation can increase energy costs.
  • The exhaust fans are the ventilation. A bath fan and a kitchen range hood take moisture and cooking products out of the house. Where they discharge matters: a fan that ends in an attic is putting the bathroom's moisture into the roof structure rather than outside, which is a real finding from the walk in Walk your house.

Houses heated by a boiler, by electric baseboard or by mini-splits usually have no ducts and no central filter at all. That does not make them worse; it means the filter row on your calendar is about the units' own washable filters, on the maker's interval rather than on a published national one.

Call somebody today if: a gas appliance is running and a CO alarm sounds, in which case the instruction from CPSC is to get everyone outside to fresh air and then call 911, covered in Alarms, vents and tests.

5. Heat and cooling

Five arrangements cover most American homes. What you need from this section is which one you have, what it burns or uses, and where the combustion air and the flue go if it burns anything.

ArrangementWhat it usesHow heat movesCombustion and flue?
Furnace with ductsNatural gas, propane, oil or electricityHeated air through supply ductsYes, unless electric
Boiler with radiators or baseboardGas, propane or oilHot water or steam through pipesYes
Heat pumpElectricityMoves heat rather than making it; ducted or ductlessNo
Mini-splitsElectricityHeat pump with wall or ceiling heads, no ductsNo
Electric resistanceElectricityBaseboard or wall units, heat made in the roomNo

Combustion, in one paragraph. Anything that burns fuel needs air to burn with and a path for the products of combustion to leave. The path is a flue or a chimney, and it works because hot gas rises. When that path is blocked, corroded or disconnected, the products come into the house instead, and one of them is carbon monoxide. That is why CPSC's guidance on the annual professional inspection is specific that the inspector should also check chimneys and flues for blockages, corrosion, partial and complete disconnections and loose connections. It is also why nothing in this manual asks a householder to look inside one.

Cooling. An air conditioner and a heat pump do the same thing: they move heat from inside to outside using a refrigerant that changes state. The indoor coil gets cold, moisture condenses on it, and that condensate drains away through a line that can clog, which is one of the common ways a cooling system causes water damage. Find the condensate drain and its pan now, while nothing is wrong.

What you do not touch. Refrigerant, the gas connection, the burners, the heat exchanger, the flue. Those are in Heating, cooling and hot water as the technician's half of a clearly divided job.

Call somebody today if: you smell gas (leave the building first and call from outside); a flame that should be blue is yellow and lazy; there is soot around a vent or appliance; or the equipment is short-cycling, which is turning on and off every few minutes.

Go deeper

Why a heat pump's output falls as it gets colder

A heat pump does not make heat, it moves it, which is why it can deliver more energy into a house than it consumes. The heat it moves comes from outdoor air, and there is less of it available as the air gets colder, so the amount of heat delivered per unit of electricity falls with the outdoor temperature. That is the reason cold-climate installations carry a backup heat source, usually electric resistance elements, and the reason a heat pump system's running cost in January is a different number from its running cost in October. Which backup yours has, and at what temperature it takes over, is a question for the installer or the manual.

A vent is not a flue

Both words get used loosely. In this manual a flue carries the products of combustion out, and a vent in the plumbing sense lets air into the drain system so traps are not siphoned. A dryer duct and a bath fan duct are sometimes also called vents, which is a third use. When somebody says vent to you, ask which of the three they mean before you agree to anything.

A pressure reducing valve

Some water services arrive at a pressure higher than a house's fixtures are designed for, and a pressure reducing valve near the main shutoff brings it down. They wear out, and when one does the house pressure can rise. If you have one, note it on the systems sheet, because a plumber will ask. We found no agency or extension source giving a homeowner a target range, so this manual states none and the question goes to the plumber or the utility.

GFCI and AFCI

Two protective devices with different jobs, both found as outlets or as breakers. A GFCI (ground fault circuit interrupter) opens the circuit when current is leaking to ground, which is the shock hazard, and is why they appear near water. An AFCI (arc fault circuit interrupter) opens the circuit on the electrical signature of an arc, which is a fire hazard. Both have test buttons. We did not find an agency or extension publication giving a homeowner a testing interval, so this manual gives none, and the device's own instructions are the authority. InterNACHI's chart notes that a GFCI could last 30 years, but much less if tripped regularly, which is a useful reminder that these are wearing parts rather than permanent features.

Mobile and manufactured homes, condos and rentals

A manufactured home's systems are arranged differently from a site-built house's, and some of its components and some of the rules that govern them are specific to manufactured housing; your state agency is where to ask which. In a condo or co-op, the boundary between what the unit owner maintains and what the association maintains is set by the association's own documents and by nothing else, including this manual. In a rental, the lease and your state's landlord-tenant law set it. In all three cases the map above is still the map; what changes is who owns which part of it.

6. Power

Power arrives through a service drop or lateral, passes through the utility's meter, and enters the panel, where a main breaker can disconnect the whole house. From the main, branch circuits run out to the rooms, each protected by its own breaker sized to the wire behind it.

The one number to write down is the service size, stamped on the main breaker: 100, 150 or 200 amps in most houses. It is the ceiling on what the house can run at once, and it is the first question asked by anybody quoting a heat pump, an electric water heater, a range or a car charger.

What a householder does with a panel is small and specific: read the labels, correct them if they are wrong by testing which breaker controls what, and reset a tripped breaker once. Test it A breaker that trips once may have been a one-time overload. A breaker that trips again is reporting something, and the thing it is reporting is a question for an electrician rather than for a bigger breaker. Replacing a breaker with a larger one to stop it tripping removes the protection the wire was given.

Caution

The cover stays on. This manual gives no instruction for opening an electrical panel, changing a breaker, or working on wiring or a service entrance. Hire a licensed electrician, and verify the license with your state or county rather than with the electrician, which is FTC's advice and the method in Hiring help.

Call somebody today if: a breaker trips repeatedly; anything is warm, discolored or buzzing at an outlet or switch; lights dim noticeably when a large appliance starts; or there is a burning smell with no source you can find.

7. The shell

The shell, or building envelope, is the boundary between conditioned inside air and the outdoors: roof, walls, windows, doors, and the floor or foundation. DOE's Energy Saver Guide defines it the same way, as the parts of the home that separate the interior from the outside elements, and notes that the greater the difference between the indoor and outdoor temperatures, the more energy it takes to hold a comfortable one.

Two layers in the shell do two different jobs, and confusing them is the most common homeowner mistake in this part of a house.

  • The air barrier stops air moving through the assembly. Caulk, sealant, gaskets and weatherstripping are air barrier work. DOE's guide puts caulking and sealing first in its order of operations and says that after you complete air sealing, consider whether you need to add insulation.
  • The insulation slows heat moving through the assembly. Its performance is stated as an R-value, which DOE defines as a measure of resistance to heat flow, higher being more insulating, and which is printed on the batt, the roll or the packaging.

Insulation over an unsealed ceiling plane does not do what the package says, because air is carrying heat and moisture straight past it. That is why the order matters, and Air, moisture and insulation gives the DOE table and the measurement.

The attic and the crawl space are where several systems meet, which is why they get walked. Ducts, wiring, plumbing, the flue, the insulation and the bath fan terminations are all up there or down there, and most of the evidence of a problem elsewhere in the house shows up at one of those two places first.

8. See it See it

Fictional example

Marisol Reyes, a 1996 two-story in Austin, Texas, bought in March. Slab on grade, no basement, attic with blown insulation, irrigation system, public water and sewer. Heat pump installed 2018, electric tankless water heater 2022.

Known. Tracing water in took twenty minutes: meter in a box at the sidewalk, main shutoff in the garage wall beside the water softener loop, cold branches up through the slab, and the tankless unit on the garage wall rather than a tank in a closet. Water out: all public sewer, so her water-out section ends at the property line. Air: the heat pump is ducted, the filter is a 20 by 25 by 1 behind a ceiling return grille in the upstairs hall, and both bath fans discharge through the roof rather than into the attic, which she confirmed from the ground.

Assumed, and the assumption is hers: that the condensate line from the indoor coil drains to the outside wall she found a stub of pipe on. She has not watched water come out of it. The assumption is labeled on her sheet, and what would settle it is watching the stub on a humid afternoon with the cooling running.

Still open, and who settles each: whether the attic ducts are sealed, which she cannot see from the hatch and which a contractor or an energy auditor would assess; what her static water pressure is and whether there is a pressure reducing valve (a plumber); and whether her panel has capacity for an electric car charger, which is a question for an electrician and which starts with the 150 amps she read off the main breaker.

Her heat pump has no combustion and no flue, so the whole combustion half of this chapter is reading rather than doing for her. Her gas range, if she had one, would put it back.

9. Practice Practice

Minimum: the three traces in Start here, which produce three facts for the systems sheet. Time: about 45 minutes for the minimum, two hours for all six systems. Materials: a flashlight, a tape measure, a phone camera, and the systems sheet open.

  1. Trace water in from the meter to the water heater, touching each thing as you name it. Write the main shutoff's location in words a stranger could follow.
  2. Find a fixture stop valve under one sink and turn it off and on. This is the small version of the main shutoff test and it takes a minute.
  3. Pull the air filter out and read its size off the cardboard edge. Write the size, not the brand. Three numbers, like 20 by 25 by 1.
  4. Open the panel door, read the service size off the main breaker, and read the circuit labels. The cover stays on. Note any label that is blank or obviously wrong.
  5. Write one sentence per system on the systems sheet saying what you have, where its control is, and what you could not find.
Go deeper

Two longer exercises. Map the branch circuits: with one person at the panel and one with a lamp, work through the house and correct every label, which takes an afternoon and is the single most useful hour anybody spends with a panel door open. And find the condensate drain for your cooling system, follow it to where it discharges, and watch water leave it on a humid day, so that you know what normal looks like before it clogs.

10. Your house Your house

11. Check your work Check your work

Criteria

  • Can you name the control for all six systems, and say where each one is without going to look?
  • Does your filter size have three numbers in it? A filter described as "the big one" is not a record.
  • Did you write down the systems you could not identify, rather than leaving them blank? Blank reads as not looked at.
  • For any system that burns fuel, can you say where the flue goes and where the combustion air comes from, without having opened anything?
  • Do you know which of the five call-somebody-today symptoms apply to equipment you actually have?

Worked example

Marisol passes on four criteria and fails on one. She can name every control, her filter is recorded as 20 by 25 by 1, she wrote down that she could not assess the attic ducts, and her equipment has no combustion so the flue criterion does not apply. What she missed is the condensate line: she recorded it as a location rather than as something she had seen working, and the sheet now says "assumed" against it, which is the honest entry and also a row on the ranked job list for the next humid afternoon.

Common mistakes

  • Learning the map and then opening something. Understanding how a flue works is the point of this chapter. Looking inside one is not an application of it.
  • Assuming a system exists because houses usually have one. Plenty of houses have no central filter, no fixture stop valves, no attic access and no condensate pan. Record what is there.
  • Recording the brand instead of the number. Filter size, service size and model number are the facts that get used later; brands get discontinued.
  • Confusing the three meanings of vent. Plumbing vent, dryer vent and combustion flue are three different things with three different failure modes, and a contractor using the word loosely can be agreed with by accident.
  • Putting a bigger breaker in to stop a nuisance trip. The breaker is sized to the wire. Making it bigger removes the wire's protection.

What is still unresolved

This chapter does not tell you the condition of anything. It tells you what you have and where its controls are. Condition is partly What wears out and when, which puts a published service life beside each component, and partly the job of the trades listed in the who-to-call table, who can assess the things you cannot see. Nor does it tell you what any of it costs to run; that is What upkeep costs and, for appliances, Choosing and keeping appliances.

12. Knowledge check and scenario

A guest bathroom nobody uses has started to smell faintly of sewage. What is the likely mechanism?
The trap under one of its fixtures has evaporated, so there is no longer a plug of water blocking the drain. Pouring a cup of water down each drain restores it. If the smell comes back quickly in a fixture that is being used, that is a different problem and worth a plumber.
Your neighbor says a better furnace filter will improve your indoor air quality. What is true and what is missing?
A better filter does clean the air that is already circulating, and EPA recommends a filter rated at least MERV 13 or as high as the system will accommodate. What is missing is that filtration is not ventilation: it removes nothing that is being produced continuously at the same rate, and EPA names source control as the first and usually cheaper strategy. The system's own capacity is also a limit, covered in Air, moisture and insulation.
Why does this chapter ask you to write down the service size in amps?
Because it is the ceiling on what the house can run at once, and it is the first question asked by anybody quoting electric heating, an electric water heater, a range or a car charger. It is stamped on the main breaker and readable with the panel cover on.
(Go deeper) Why does a heat pump need a backup heat source in a cold climate?
Because it moves heat from outdoor air rather than making it, and there is less heat available in the air as it gets colder, so its output falls with the temperature. Which backup your system has, and at what outdoor temperature it takes over, is a question for the installer or the manual.
You are tracing the air system and you find that the upstairs bath fan duct ends in the attic rather than going through the roof or a wall. What is the right next move?
This is a real finding and a real row on the job list: a fan discharging into the attic puts the bathroom's moisture into the roof structure, which is the mechanism behind several of the problems in Air, moisture and insulation. It is not an emergency, and the walk is not the time to fix it.
Turning the fan off moves the moisture into the bathroom instead of into the attic, which is the problem the fan exists to solve. Keep using it and get the duct routed outside.
Routing a fan duct is within reach for some people, and a soffit vent is the wrong place to end one, because it can draw the moist air straight back into the attic. If you take this on, find out where your roof assembly is designed to discharge it; if you are not sure, it is a contractor's half-day.

Checklist

Records your learning only; it is not a qualification.