Published service lives, by system
Reference

Published service lives, by system

A filterable table of published service life estimates with the publisher named in every row, and a plain statement of what the chart behind them does and does not carry.

Every figure below comes from one publisher, and the Publisher column says so on every row. Use the filter buttons to narrow the table to one system, or type into the box to find a component by name.

Limits

The chart these figures come from carries no publication date and no methodology statement. InterNACHI's estimated life expectancy chart does not say when it was compiled, from what data, or how the figures were derived. That is a real limit on how much weight any single number here should carry. Treat each figure as a trade association's compiled estimate rather than a prediction for your component, and let your own evidence, which is the install date on the plate, the service history and your own log, overrule it whenever you have some. What wears out and when explains how to use a figure like this and what beats it.

What a figure here is for: it tells you roughly when to start asking a question about a component, not when to replace it. A component inside three years of its published figure is one to price, to fund, and to get an opinion on. The reserve calculator turns a figure and a replacement cost into an annual set-aside.

ComponentPublished figure (years)Publisher
Furnace15 to 25InterNACHI
Boiler (hot water or steam radiant)40InterNACHI
Heat pump10 to 15InterNACHI
Air conditioner (central)7 to 15InterNACHI
Air conditioner (window)5 to 7InterNACHI
Heat exchanger10 to 15InterNACHI
Condenser8 to 20InterNACHI
Burner10 or moreInterNACHI
Ducting60 to 100InterNACHI
Diffusers, grilles and registers25InterNACHI
Dampers20 or moreInterNACHI
Thermostats35InterNACHI
Evaporative cooler15 to 25InterNACHI
Gas fireplace15 to 25InterNACHI
Electric radiant heater40InterNACHI
Heat-recovery ventilator20InterNACHI
Attic fan15 to 25InterNACHI
Chimney cap (metal)10 to 20InterNACHI
Chimney cap (mortar)15InterNACHI
Chimney cap (concrete)100 or moreInterNACHI
Chimney flue tile40 to 120InterNACHI
Water heater (conventional tank)6 to 12InterNACHI
Water heater (instant, on demand)10InterNACHI
Copper water lines70InterNACHI
Water line (copper)50InterNACHI
Water line (plastic)50InterNACHI
Plastic water lines75InterNACHI
PEX40InterNACHI
ABS and PVC waste pipe50 to 80InterNACHI
Cast-iron waste pipe (above ground)60InterNACHI
Cast-iron waste pipe (below ground)50 to 60InterNACHI
Faucets and spray hose15 to 20InterNACHI
Toilet tank components5InterNACHI
Hose bibs20 to 30InterNACHI
Sump pump7InterNACHI
Well pump15InterNACHI
Water softener20InterNACHI
Sewer grinder pump10InterNACHI
Vent fan (ceiling)5 to 10InterNACHI
Gas lines (black steel)75InterNACHI
Gas lines (flexible)30InterNACHI
Asphalt shingles (3-tab)20InterNACHI
Asphalt (architectural)30InterNACHI
Metal roofing40 to 80InterNACHI
Slate60 to 150InterNACHI
Clay or concrete tile100 or moreInterNACHI
Wood roofing25InterNACHI
Fiber cement roofing25InterNACHI
Modified bitumen20InterNACHI
Built-up roofing (BUR)30InterNACHI
EPDM rubber15 to 25InterNACHI
TPO7 to 20InterNACHI
Roofing adhesives and cements15 or moreInterNACHI
Aluminum gutters, downspouts, soffit and fascia20 to 40 or moreInterNACHI
Galvanized steel gutters and downspouts20InterNACHI
Vinyl gutters and downspouts25 or moreInterNACHI
Copper gutters50 or moreInterNACHI
Insulation batts and rolls100 or moreInterNACHI
Loose-fill insulation100 or moreInterNACHI
Cellulose insulation100 or moreInterNACHI
Fiberglass insulation100 or moreInterNACHI
Housewrap80 or moreInterNACHI
Black paper (felt paper)15 to 30InterNACHI
Caulking (interior and exterior)5 to 10InterNACHI
Sealants8InterNACHI
Paint (exterior)7 to 10InterNACHI
Paint (interior)10 to 15InterNACHI
Door gaskets and weatherstripping5 to 8InterNACHI
Vinyl siding60InterNACHI
Aluminum siding25 to 40 or moreInterNACHI
Stucco and EIFS50 or moreInterNACHI
Exterior trim25InterNACHI
Service panel60InterNACHI
Ground-fault circuit interrupters (GFCIs)up to 30, and much less if tripped regularlyInterNACHI
Arc-fault circuit interrupters (AFCIs)30InterNACHI
Bare copper wiring100 or moreInterNACHI
Copper-clad aluminum wiring100 or moreInterNACHI
Light fixtures40InterNACHI
Lighting controls30 or moreInterNACHI
Residential propane backup generators12InterNACHI
Solar panels20 to 30InterNACHI
Solar system batteries3 to 12InterNACHI
Refrigerator9 to 13InterNACHI
Freezer10 to 20InterNACHI
Dishwasher9InterNACHI
Washing machine5 to 15InterNACHI
Clothes dryer13InterNACHI
Dryer vent (plastic)5InterNACHI
Dryer vent (steel)20InterNACHI
Electric range13 to 15InterNACHI
Gas range15 to 17InterNACHI
Gas oven10 to 18InterNACHI
Range or oven hood14InterNACHI
Microwave oven9InterNACHI
Food waste disposal12InterNACHI
Dehumidifier8InterNACHI
Exhaust fans10InterNACHI
Asphalt driveway15 to 20InterNACHI
Concrete walks40 to 50InterNACHI
Brick and concrete patio15 to 25InterNACHI
Wood fencing20InterNACHI
Irrigation sprinkler heads10 to 14InterNACHI
Irrigation valves20InterNACHI
Irrigation controllers15InterNACHI
Underground PVC piping60 or moreInterNACHI
Radon fan5 to 8InterNACHI
Radon system piping50 or moreInterNACHI

How to use a row

  1. Copy the figure and the word InterNACHI into the same row on the systems sheet. A number on a sheet without its publisher is a number nobody can check in two years, including you.
  2. Subtract your install date from the figure and write the year money is likely needed, as a year rather than a count of years.
  3. Where you could not establish an install date, write unknown and give the component the earliest plausible replacement year with the reason beside it.
  4. Where your own evidence disagrees with the figure, follow your evidence and record both. Rust at the base of a tank outranks any table.

About the ranges

Many rows give a range rather than a single figure, and a wide one: a central air conditioner at 7 to 15 years, a washing machine at 5 to 15. A range that wide is telling you that the population varies enormously, which is exactly the situation in which your own evidence is worth more than the table. Four things move a real component within its range, and all four are observable: water, sun and weather, how many hours the equipment runs, and whether anybody serviced it. What wears out and when covers each.

For planning, the conservative use of a range is the low end, because a reserve built on the low end is a reserve that is ready early. The optimistic use is the high end, which is a position rather than a plan.

Figures this table does not carry

Three kinds of number are deliberately absent.

  • Replacement costs. This manual ships none, because we did not find a dated, citable national cost set worth building on. A local quote is better evidence and usually free. What upkeep costs says why.
  • Finishes. Floors, counters, cabinets and tile have published figures too, and they are mostly tier 5 in The priority rule. Learn Home Finishes on this shelf works through those materials.
  • Anything from a source we could not fetch. We looked for a second trade-association table to put beside this one and the study we wanted returned a dead link on the publisher's own site, so this table cites one publisher and says so rather than quoting a figure we could not open.

The full chart, including the sections on cabinetry, countertops, flooring and framing that this table leaves out, is at InterNACHI's estimated life expectancy chart. One of its own rows notes that an acoustical tile ceiling older than 25 years may contain asbestos, which is a reminder that an old component can carry a question that has nothing to do with how long it lasts.